Gamma Ray Shielding Glass

PRO GR

QUOTE||800.426.0279

Gamma Ray Shielding Glass


Pro-GR lead shielding glass was developed to protect against high radiation gamma rays used in PET scan facilities. Pro-GR is made of glass materials having a lead oxide content rate of roughly 70% that is equivalent to ultra-high lead content block glass for nuclear power facilities. Pro-GR has a radiation shielding capability higher than that of conventional LX-57B.

"Architecture is inhabited sculpture."

-Constantin Brancusi

KEY FEATURES




  • Comprised of glass materials having a lead oxide content rate of roughly 70%
  • Equivalent to ultra-high lead content block glass for nuclear power facilities
  • Available in two thicknesses, LX 14.7 (14.7 mm) and LX 21.8 (21.8 mm)
  • Pro-GR has a radiation shielding capability higher than LX-57B X-Ray shielding lead glass

APPLICATIONS


Ideal for use in PET Scan facilities.

STATISTICS



Shielding Performance Against Gamma Rays

In calculating the shielding performance of Pro-GR against 0.511 MeV gamma rays, the Monte Carlo simulation is used to calculate the build-up factor of Pro-GR glass, and calculates the effective dose transmission factor in accordance with the Manual for Shielding Calculation of Radiation Facilities, 2000 (issued by the Nuclear Safety Technology Center). In calculating the lead equivalent of Pro-GR, the thickness of Pro-GR was designed so that the effective dose transmission factor is equivalent to the effective dose transmission factor of lead calculated by taking the build-up factor into account as shown in the following table.


Effective Dose Transmission Factor Of Lead For 0.511 Mev Gamma Rays And Thickness Of Pro-GR Corresponding To Each Thickness Of Lead

LEAD PRO-GR
Thickness Effective Dose Transmission Factor Pro-GR Thickness Recommended
(Corresponds to Lead Effective Dose Transmission)
Recommended Product
5.0 mm
[1.21]
52.6 14.2 mm
[1.33]
Pro-GR
14.7 mm
7.5 mm
[1.25]
36.0 21.3 mm
[1.45]
Pro-GR
21.8 mm
Note: Numbers in brackets [ ] are reference values and are the build-up factors of Lead and Pro-GR.
In the case of 0.2 MeV X-Rays, the effective dose transmission factor of lead at 5mm thickness is 0.48% and 7.5mm is .0.033%

PERFORMANCE DATA


  PRO-GR 14.7 PRO-GR 21.8
Thickness (mm) 14.7 21.8
Effective Dose Transmission Factor* (%) 52.6 36.0
Lead Equivalent (mmPb) 5.0 7.5
Minimum Size 42” x 60” (1000 mm x 1500mm) 42” x 60” (1000 mm x 1500mm)
Specific Gravity Min. 5.20 Min. 5.20
Knoop Hardness 320 320
Visible Light Transmission 83% 83%
*Values for effective dose transmission factor and lead equivalent are for gamma rays (0.511 MeV)
Note: "Seeds" or minute air bubbles exist inside Pro-GR as it is made of special glass materials. This, however, does not adversely affect its radiation shielding performance.

DOCS & DOWNLOADS


Product Fact Sheet